bittorrent synch 1.3.109

BTSync-1.3.109.exe — without webgui. For win xp & w2k3

Практикум_ Обзор BitTorrent Sync

Установка, настройка и использование BitTorrent Sync

спасибо за инфу

с новыми версиями возникли проблемы с web gui, а новая 2.3 вообще ни где не открывалась.

linux
btsync_i386-1.3.109.tar

btsync_x64-1.3.109.tar

btsync_arm-1.3.109.tar

scm login

ibm_sw_scm-2.20.0_anyos_i386
https://ip_address:32101/ibm/console/logon.jsp

Configuring security
To prevent unauthorized access to your managed devices, you should configure
several types of security settings.
v To prevent an unauthorized Windows user from logging in to the managed
device, ensure that guest account credentials are properly configured. See
“Configuring Windows guest credentials” on page 24
v When installing a managed device, change any user passwords immediately
after installation. See the IBM Storage Configuration Manager online help for
information on changing SAS Switch and RAID Subsystem passwords through
IBM Storage Configuration Manager.
v To configure storage, ensure that the host login credentials you are using have
administrator privileges on the Windows operating system or root privileges on
the Linux operating system.
Secure Web browser connections
When you use a Web browser to connect to IBM Storage Configuration Manager,
use the following tips to establish a secure connection.
v Always specify a Web address that begins with https: to force your browser to
use the encrypted Secure Socket Layer (SSL) protocol. Addresses that begin with
the http: prefix are insecure and vulnerable to eavesdropping, tampering, and
message forgery.
v After installing IBM Storage Configuration Manager, you should replace the
temporary SSL certificates with official ones. For details, refer to:
http://wilson.boulder.ibm.com/infocenter/usmitk/v1r0/index.jsp?topic=/
com.ibm.usmi.lwi.doc/lwi_config_lightweightruntimesslconfiguration.html
v If you use IBM Storage Configuration Manager in a tabbed Web browser, click
the Logout link in IBM Storage Configuration Manager to securely end your
session. Closing the IBM Storage Configuration Manager tab does not log you
out. You can also close the browser window (all tabs) to end your session.
v If you cannot view the IBM Storage Configuration Manager console in Internet
Explorer, perform the following steps to ensure the site is added to your
browser’s list of trusted sites:
1. Select Tools → Internet options → Security → Trusted sites.
2. Click Sites.
3. Click Add.
4. Click Close.
© Copyright IBM Corp. 2008, 2010 23
5. Click OK.
Configuring Windows guest credentials
To prevent an unauthorized Windows user from logging in to IBM Storage
Configuration Manager, ensure that guest account credentials are properly
configured.
To configure the guest credentials, perform the following steps:
1. Select Control Panel → Administrative Tools → Computer Management.
2. Select Local Users and Groups → Users → Guest.
3. Make sure that the Guest user name and password fields are not empty.
Note: Guest accounts are not supported in IBM Storage Configuration
Manager. Guest accounts cannot change configuration options.
Connecting to IBM Storage Configuration Manager
You can connect to IBM Storage Configuration Manager by starting the IBM
Storage Configuration Manager Launch Manager on that machine using the
following installed menu shortcuts.
Table 9. Shortcut to start IBM Storage Configuration Manager Launch Manager
Operating system Shortcut
Linux (KDE) Desktop → IBM Storage Configuration Manager → IBM Storage
Configuration Manager
Windows Start → Programs → IBM Storage Configuration Manager → IBM
Storage Configuration Manager
You can also connect by starting a Web browser and entering the appropriate URL.
Notes®:
v You can choose where to install IBM Storage Configuration Manager shortcuts
during the installation. The default on Linux is /USER_HOME/Desktop . The
default on Windows is Start->Programs.
v For security reasons, you must enter a URL that begins with the https: prefix.
For details, see “Secure Web browser connections” on page 23.
v To use your preferred Web browser with IBM Storage Configuration Manager,
you might have to perform some configuration. For details, see Chapter 4,
“Configuring Web browsers,” on page 13.
v If you cannot view the IBM Storage Configuration Manager console in Internet
Explorer, ensure the site is added to your browser’s list of trusted sites. For
details, see “Secure Web browser connections” on page 23.
v IBM Storage Configuration Manager does not support the Back and Forward
buttons of Web browsers (or equivalent keyboard shortcuts). Clicking these
buttons while connected to IBM Storage Configuration Manager causes
unexpected behavior. Use only the navigation buttons provided by the IBM
Storage Configuration Manager in the browser window.
This example connects from a Web browser on the machine where IBM Storage
Configuration Manager is installed (localhost):
https://localhost:32101/ibm/console/logon.jsp
24 IBM Storage Configuration Manager 2.20.0: Planning, Installation, and Configuration Guide
This example connects from a Web browser on a different machine, using an IP
address to specify the machine where IBM Storage Configuration Manager is
installed:
https://IP_address:32101/ibm/console/logon.jsp
Logging in
After connecting your Web browser to IBM Storage Configuration Manager, log in
by entering your operating system ID and password. To access RAID controller
functions, ensure that the host login credentials you are using have administrator
privileges on the Windows operating system or root privileges on the Linux
operating system.
Important:
v The operating system password must not contain the % character. Use of this
character in the password prevents the browser from accessing IBM Storage
Configuration Manager pages.
v If your operating system password changes while you are logged into IBM
Storage Configuration Manager, you will be disconnected from the server. Any
functions on the current page will no longer work, and navigating to a different
IBM Storage Configuration Manager page redirects to the login page. This
behavior is normal, and you will need to use your new password to log back in
to IBM Storage Configuration Manager.
If IBM Storage Configuration Manager is installed on a Windows server configured
with multiple domains, you must specify the domain by entering the username in
the following format:
username@domain
For example, to log in as administrator on the 7z4A.local domain, enter your
username as:
administrator@7z4A.local
Attention: If guest credentials are not properly configured, it is possible for an
unauthorized user to log in to IBM Storage Configuration Manager. For
instructions on how to prevent this from happening, see “Configuring Windows
guest credentials” on page 24.

IBM SAS RAID Controller Module (43W3584) documentation — IBM BladeCenter S Chassis

IBM Systems Director 6.3.7

IBM Systems Director 6.3.7 update

doc

resouces

HP number for 3C16476BS is JE731A

BASELINE_50_PT_SMART_FE_SWITCH_v.1.01_3com_detect_01_01.exe

BASELINE_50_PT_SMART_FE_SWITCH_v.1.0.1.5_3C16476BS_V1_0_1_5.exe

3com 3cr17562-91 или HP 4500-48 Switch JE046A прошивка

E4500_03.03.02p21_E4500_03.03.02p21
прошивки, MIB, soft

Прошивка через web морду, с указанием файла прошивки новой и старой, которую нужно затереть привели после ребута ошибке в браузере. 404 нет файла для web морды.
Ставлю Filezillу.
Дальше нужно лезть через telnet (putty) >
> авторизироваться
> ftp мой_ip
> get s3n03_03_02s56p04.app s3n03_03_02s56p04.app
> get s3o04_02.btm s3o04_02.btm
> get s3p04_02.web s3p04_02.web
> bye
> reboot
Так заливается на этом чуде прошивка. Задница вообщем, но уж лучше чем avaya и гарантия 100 лет.

vnc4server for gui

#sudo apt-get install gnome-core
#sudo apt-get install vnc4server
#vncserver -geometry 1280×1024 -depth 24
#vncserver -kill :1
#cd
#sudo vi .vnc/xstartup

should be: (look at reference link as does not format well on forum)

#vncserver -geometry 1280×1024 -depth 24

(reference for gnome and vnc http://www.havetheknowhow.com/Configure-the-server/Install-VNC.html)

Когда нужно поднять графику без монитора.
Или использовать framebuffer, dummy.

vnc xenserver vm
xenserver65sp1_vm_users_guide

kyocera + ad

Прошивка cisco 7940

pro-voip.com.ua/cisco-7940-firmware-upgrade-sccp-sip
bos-info.com/asterisk/cisco-7960g-%D0%B8-7940.html
cisco 7940
dialplan.xml

<DIALTEMPLATE>
<TEMPLATE MATCH="1.." TIMEOUT="1"/><!-- Internal extensions 100 to 199. Wait 1 second, then dial. -->
<TEMPLATE MATCH="2.." TIMEOUT="1"/><!-- Internal extensions 200 to 299. Wait 1 second, then dial. -->
<TEMPLATE MATCH="......." TIMEOUT="1"/><!-- 7 digits. Wait 1 second, then dial. -->
<TEMPLATE MATCH=".........." TIMEOUT="1"/><!-- 10 digits. Wait 1 second, then dial. -->
<TEMPLATE MATCH="1.........." TIMEOUT="0"/><!-- 1+10 digits. Dial immediately -->
<TEMPLATE MATCH="\*86" TIMEOUT="0"/><!-- *86 (*VM) for voicemail. Dial immediately. -->
<TEMPLATE MATCH="*#" TIMEOUT="0" REWRITE="%1"/><!-- Dial immediately after pressing #. -->
<TEMPLATE MATCH="*" TIMEOUT="3"/> <!-- Anything else -->
</DIALTEMPLATE>

 

RINGLIST.DAT
Old Style ringer1.pcm
Synth Low ringer2.pcm
Dungeon ringer3.pcm
Lightbulb ringer4.pcm
Synth High ringer6.pcm
ClockShop ClockShop.raw
Drums 2 Drums2.raw
FilmScore FilmScore.raw
FlintPhone FlintPhone.raw
HarpSynth HarpSynth.raw
Jamaica Jamaica.raw
KotoEffect KotoEffect.raw
MusicBox MusicBox.raw
Neuro Neuro.raw
Ohno Ohno.raw
Piano 1 Piano1.raw
Piano 2 Piano2.raw
Pop Pop.raw
Pulse Pulse1.raw
Saxaphone 1 Sax1.raw
Saxaphone 2 Sax2.raw
MayIHelp mayihelp.raw
Dilbert Boss SICA-dilbert-BungeeBoss.raw
CTU24raw CTU24raw.raw

Прошивка avaya / nortel 4500

There are two things You have to know before You start planing an upgrade your ERS 5xxx switches. First You need active service/support contract to download firmware from avaya support portal. Second firmware versions should be upgraded one by one, You cannot apply only last firmware release.

Upgrading firmware have a few steps:

Download proper diagnostic and image files from http://support.avaya.com
For the purposes of this post, lets asume that we will upgrading diagnostic image to version 6.0.0.15 and firmware image to 6.2.4.011.
Start tftp server, that will host image files for upgradeing device
And again, for this example, lets asume that tftp server will be listning on ip 192.168.1.9/24, and switch ip will be 192.168.1.10/24.
Place diagnostic image (*.bin) and firware image (*.img) in the tftp servers root directory.
Start Nortel/Avaya ERS device, and configure switch ip address

ERS5520>enable
ERS5520#configure terminal
ERS5520(conf)# ip address switch 192.168.1.10 255.255.255.0 default-gateway 192.168.1.1
ERS5520(conf)# exit
ERS5520# show ip address switch
Configured In Use Last BootP/DHCP
————— ————— ———————
Switch IP Address: 192.168.1.10 192.168.1.10
Switch Subnet Mask: 255.255.255.0 255.255.255.0
ERS5520#ping 192.168.1.9
Host is reachable

Upgradeing diagnostic image

ERS5520#download address 192.168.1.9 diag 5xxx_60015_diags.bin
Downloading Diag Image [/]
Saving Diag Image [\]
Finished Upgrading Diag Image
Rebooting

Switch should reboot automatically.
Upgrading firmware image

ERS5520#download address 192.168.1.9 image 5xxx_624011s.img
Downloading Image [\]
Saving Image [/]
Finished Upgrading Image
Rebooting

Switch should reboot again automatically.

After that steps You can log into the CLI of Your ERS device and check version of diagnostic image and firmware image:

ERS5520>enable
ERS5520#show sys-info
[…]
sysDescr: Ethernet Routing Switch 5520-24T-PWR
HW:33 FW:6.0.0.15 SW:v6.2.4.011
[…]
ERS5520#

This entry was posted in Networking on December 17, 2014.
Post navigation